MOBIUS OEAM — Operational Energy & Asset Management
MOBIUS SOFTWARE
ISO 50001 · Energy ISO 55001 · Assets EN 50160 · Power Quality EFFI-100 & Seismic Protection Integrated with MOBIUS UEAM
Operational Energy & Asset Management

MOBIUS OEAM

The platform that brings together energy, technical assets and costs in a single decision system. It turns consumption data (electricity, water, gas, thermal energy, environmental parameters) into normalized indicators, contextual alerts, intervention tickets in MOBIUS UEAM and verifiable reports.

Architecture from Sensor to Intervention Ticket

Each energy deviation is correlated with the asset, the process and the operating schedule, without replacing certified local protections or automation.

  • Multi-protocol acquisition: Modbus TCP/RTU, BACnet, OPC UA, IEC 61850, MQTT, SCADA/BMS
  • EFFI-100 / effiPower hardware layer: N1 (Visibility), N2 (Diagnostics), N3 (Savings) analysis + offline buffer
  • DASS seismic protection (M95 XL): safe-state shutdown and automatic inspection tickets in UEAM
  • Energy audit & ISO 50001: baseline, EnPIs and real verification of savings with certified experts
📚 Library of technical PDF presentations (5 documents) →
7 Modulesactivated progressively, from an operational MVP to AI/ML
3 EFFI LevelsN1 Visibility · N2 Diagnostics · N3 Savings
ISO 50001 + 55001energy, asset condition, EN 50160 and CSRD
100% Traceablecomplete flow: anomaly → alert → UEAM ticket → confirmation
The Operational Concept

Energy becomes an operational resource, not just a monthly bill.

MOBIUS OEAM is not just a monitoring system. It is the platform through which energy information becomes technical, financial and managerial action: it links the consumption of electricity, water, gas and thermal energy to asset condition, operating schedule, maintenance and costs.

The fusion of ISO 50001 (energy management) and ISO 55001 (asset management) turns any increased consumption for the same output into an early diagnostic tool for the wear of a pump, blower, boiler or HVAC installation.

MOBIUS OEAM Energy · Assets · Decision · Compliance
01 · Remote reading & EdgeMeters, EFFI-100, SCADA
02 · Asset contextStation → line → asset hierarchy
03 · Alerts & TicketsDirect flow into MOBIUS UEAM
04 · ISO 50001 & CSRDEnPIs, baseline, ANRE audit
05 · Costs & BalancekWh/m³, kWh/tonne, kWh/m²
06 · Safety & AIAnomalies & seismic protection
PILLAR 01 · DATA Measurement & Validation Remote reading of meters and analyzers (electricity, water, gas, thermal, CO₂); timestamping, offline buffer and normalization.
PILLAR 02 · CONTEXT Assets & Processes Correlating consumption with the technical asset, flow, pressure, schedule, weather, tariffs and cost center across the entire lifecycle.
PILLAR 03 · ACTION Dispatch & UEAM Ticket Alerts without duplicates, triage by criticality, assignment to the specialized team, SLA deadline and confirmation of return to normal parameters.
PILLAR 04 · RESULT Savings & Compliance Savings verified against the reference profile (baseline), reports for management, ISO 50001, ANRE, EN 50160 and sustainability (CSRD).
Functional Architecture · 7 Modules

Seven modules activated progressively. A single flow from data to decision.

Implementation can start with an operational core (MVP / pilot project) and be extended gradually, without dependence on a single equipment manufacturer.

MODULE 01

Acquisition and integration

Smart meters, network analyzers (EFFI-100 / PM5330), IoT sensors (CO₂, temperature, pressure), programmable logic controllers (PLCs), SCADA, BMS and ERP via Modbus TCP/RTU, BACnet, OPC UA, IEC 61850 and MQTT.

Vendor-independent
MODULE 02

Real-time monitoring

Executive and technical dashboards, synoptic views by building/level/station, continuously updated performance indicators, 24h load curves, multi-site comparison and mobile access.

Company → asset hierarchy
MODULE 03

Alerts and dispatch

Fixed and dynamic thresholds, persistence rules, elimination of false alerts, classification on 4 levels (Information, Warning, Critical, Emergency) and automatic ticket generation in MOBIUS UEAM.

Escalation by competence
MODULE 04

Analysis and diagnostics

Energy balance by level, a reference profile (baseline) adjusted for operating regime and seasonality, specific consumption (kWh/m³, kWh/tonne, kWh/m², kWh/pupil, kWh/bed) and power quality (EN 50160, THD).

Technical diagnostics & wear
MODULE 05

Optimization and assisted control

Peak shaving, shifting cyclical loads (filter washing, sludge presses, heating) to low-tariff periods and battery storage — exclusively with local approvals and interlocks.

No bypassing of protections
MODULE 06

Reporting and compliance

Automatic reports for ISO 50001, ANRE, energy audits (Law 121/2014), carbon footprint / CSRD, cost centers, sub-billing (internal invoicing) and PDF / Excel / CSV exports.

ISO 50001 · ANRE · CSRD
MODULE 07

Advanced analytics (AI / ML)

Consumption forecasting (1–72 hours), early anomaly detection, energy signatures of critical equipment (SoH, RUL) and human-reviewed predictive maintenance recommendations.

Predictive maintenance
OPERATIONAL EXTENSION

Native integration with MOBIUS UEAM

A unified inventory with QR/NFC labels, GIS for networks and roads, management of intervention teams, spare parts, contracts and a complete audit history for each asset.

Energy + Assets in the same core
Integrated Hardware & Partner Components

EFFI-100 / effiPower for energy analysis and certified seismic protection.

MOBIUS OEAM makes use of the existing infrastructure and can be complemented in the field with the hardware layer EFFI-100 / effiPower for advanced measurement of electrical energy and with the automatic seismic protection devices DASS (M95 XL).

Dedicated Electrical Monitoring · EFFI-100 / effiPower

Three levels of energy analysis, activated gradually

It takes information from the main distribution boards (MDB), floor boards and the feeders of critical consumers (pumps, blowers, chillers, HVAC units) via RS485 Modbus RTU and 4–20 mA inputs, with a local buffer (store & forward) when communication is interrupted.

Level 1 (N1) — Visibility: “What is happening now?” Voltages, currents, power (P, Q, S), power factor (cos φ), frequency and total harmonic distortion (THD) on each phase; balance by level and proof of ANRE / SR EN 50160 compliance.
Level 2 (N2) — Diagnostics: “Why does the deviation occur?” Current and voltage imbalances, neutral conductor loading, the load's energy signature and automatic wear alerts (pump cavitation, clogged filters, frequent starts) sent as tickets to MOBIUS UEAM.
Level 3 (N3) — Savings: “How much does it cost and what savings are confirmed?” Cost breakdown by zone/system, avoidable penalties for reactive energy and harmonics, calculation of verified post-intervention savings and ranking of measures by payback period (ROI).
Earthquake Safety · DASS M95 XL (CE · IMQ · Asce 25-16 · EN 81-77)

Seismic protection and controlled transition to a safe state

An automatic interception device activated by seismic loading (triaxial accelerometer 1–10 Hz, 128-point FFT analysis, threshold 0.1 g / 0.0875 g, response < 5 seconds). The safety action is local and immediate, while MOBIUS OEAM / UEAM takes over the status, notifies teams and opens inspection tickets.

Fuel gas (methane / LPG) & Liquid fuel Automatic closing of the solenoid valve on positive safety and locking until human verification and pressing the physical RESET button (minimum 5 s); an automatic ticket for the Gas team.
Evacuation doors, Local alarm and Non-essential circuits Automatic fail-open unlocking of evacuation doors, local siren activation and selective shedding of non-critical circuits, keeping UPS units and generators for vital consumers.
Critical rule for Hospitals: Medical oxygen is NOT cut off globally Life support (ICU, operating theater, ventilation) remains powered during the earthquake; the system raises a sector alarm and immediately notifies clinical staff and the authorized medical gas team.
Dedicated Sector Architectures

A common modeling engine, adapted to critical and public infrastructure.

Consult and download below the detailed technical presentations for the four major fields of application where MOBIUS OEAM and MOBIUS UEAM operate in an integrated way.

01 · Regional & Municipal Water-Sewage Operators Key indicator: kWh / m³ & kWh / kg BOD

Water and Sewage Companies (with EFI 100 & Energy Audit)

Unifies energy data, process parameters (flow, pressure, level, turbidity, dissolved oxygen DO, NH₄, NO₃) and asset history across the entire water and wastewater chain: abstraction, transmission, drinking water treatment (DWTP), storage/distribution (DMA, boosters), sewerage (wastewater pumping stations) and wastewater treatment (WWTP).

  • Treatment Plants (DWTP) & Network: monitoring of stage I/II pumps, filter washing (backwash outside peak hours), UV/ozone, boosters and DMA zones.
  • Wastewater Pumping Stations: early detection of impeller clogging (increased current + reduced flow), infiltration and loss of communication.
  • WWTP Bioreactor & Sludge Line: optimization of aeration blowers (40–60% of WWTP consumption), RAS/WAS recirculation, centrifuges/presses and biogas/cogeneration.
  • Complementary services: Energy audit under Law no. 121/2014 with ANRE-certified auditors and EnPI configuration according to ISO 50001.
02 · Public Hospitals and Private Clinics Key indicator: Continuity & kWh / bed

Hospitals and Medical Facilities — Critical Infrastructure

In a hospital, energy is what keeps operating rooms, ICUs, the emergency department, the medical gas chain, sterilization and sterile air conditioning running. The platform organizes data along the hierarchy Hospital → Building → Level (Technical basement + Levels 1–5) → System → Asset → Measurement point.

  • 6 critical domains monitored: Electrical (substation/MDB, floor boards N1…N5, UPS, generators, ATS), Natural gas, Plumbing, Medical oxygen, Fire protection and medical HVAC (differential pressure, filters, CO₂).
  • A response matrix across 5 specialized teams: Electrical, Gas, Plumbing, Medical oxygen and Firefighters / Fire safety, with triage by clinical criticality.
  • The partner solution effiPower (Opex / turnkey): N1/N2/N3 energy monitoring + M95 XL seismic protection without interrupting life support.
  • Adapted for public & private: budget justification and ANRE/ISCIR compliance for public hospitals; margin protection, ROI and an ANMCS accreditation file for private clinics.
03 · Educational Institutions & Campuses Key indicator: Comfort (CO₂ / Temp.) & kWh / pupil

Schools, High Schools and Educational Buildings

Brings together in a single picture the consumption, indoor environmental quality, safety and equipment inventory for the entire school campus: the main building (technical basement, ground floor, upper floors with classrooms and laboratories), the gym and sports grounds, technical surveillance and perimeter lighting.

  • Air quality and comfort in classrooms: monitoring of CO₂, temperature and humidity correlated with the school timetable, weekends and holidays.
  • Eliminating waste outside school hours: automatic detection of uneven heating, lighting left on at night/during holidays and night-time water leaks.
  • School furniture and teaching equipment with QR codes: records in MOBIUS UEAM for desks, teacher's desks, interactive whiteboards, projectors, laboratories, fire extinguishers and first-aid kits, with reporting directly from the classroom by QR scan.
  • Security & data protection: monitoring of the technical availability of cameras/NVRs and gates, with no facial recognition and no processing of pupils' images.
04 · County & Local Administration Key indicator: Building Portfolio, DGASPC & GIS Roads

County Councils — Property, Institutions and Roads

Gives County Council management a common platform for consumption, assets, buildings, costs and interventions across the entire county portfolio, while keeping operational responsibility at the level of each subordinate institution.

  • The building portfolio and DGASPC: the County Council headquarters, DGASPC residential and day centers (continuity of hot water, heating, kitchens/laundries), county hospitals, museums, libraries and special schools.
  • County Roads Directorate (through MOBIUS UEAM): GIS representation of the road network (axes, sections, mileage, bridges, culverts, guardrails, signs), condition assessment and scheduling of works and snow clearing.
  • Road dispatch & Depots/Machinery: correlating the energy consumption of depots/workshops (in OEAM) with field interventions, machinery and material stocks (in UEAM).
  • Special Transport Permits (AST): a complete digital flow for the application, GIS route validation (tonnage/size restrictions on bridges and sections), approvals, fee calculation and controlled issuance.
The Functional Architecture in 6 Steps

From the signal in the field to decisions and verified savings.

The architecture separates the field, local collection (Edge), modeling, representation and decision — ensuring local continuity even when communication is temporarily interrupted.

01

Field

Meters, EFFI-100 analyzers, CO₂/process sensors, PLC/SCADA

02

Edge acquisition

Timestamping, plausibility validation and a local buffer without duplicates

03

Asset context

Association with the station, level, production line, schedule and tariff

04

Representation

Synoptic view by level, GIS map, 24h profile and energy balance

05

Analysis & Alert

Comparison with the dynamic baseline, diagnostics and criticality triage

06

UEAM ticket

Team assignment, field intervention, measurements and confirmation

Technical Intervention Management

A consumption deviation becomes a documented intervention.

When a pump, blower or circuit consumes more than the reference profile under the same operating conditions, the rules engine evaluates persistence and severity, then automatically opens a ticket in MOBIUS UEAM for the competent team (Electrical, Mechanical, Hydraulic, Gas, HVAC or IT).

  • Complete ticket content: time, source, parameter, value, threshold, recent curve, affected asset and potential impact
  • Separation of responsibilities: initiator, dispatcher, executing team and person responsible for acceptance/validation
  • Result-conditioned closure: the ticket is closed only after confirming that the parameter has returned to the accepted range
  • Operational learning loop: the cause, parts used and savings achieved update the asset's history and the preventive plan
01

Detection & Validation

The signal exceeds the fixed threshold or the dynamic reference profile; missing values or sensor jumps are removed.

02

Context & Triage

The building/station, level, asset, schedule and severity level (Information, Warning, Critical, Emergency) are attached.

03

MOBIUS UEAM ticket

Automatic generation with a safety procedure, required competences, SLA deadline and escalation rule.

04

Field Intervention

The team takes the task on mobile/web, isolates safely, fixes the cause and attaches measurements and photos.

05

Confirmation & Audit Trail

The platform checks that consumption has returned to the baseline and records the savings and traceability for audit.

Operational Comparison

Fragmented monitoring vs. the integrated MOBIUS OEAM + UEAM platform

The difference between simply reading meters and integrated operational management of energy and assets.

Dimension Before (Monthly bills, isolated SCADA, Excel) With MOBIUS OEAM + MOBIUS UEAM
Consumption visibility Total values read from the bill at the end of the month; impossible to separate consumption by floor, ward, production line or critical asset. Real-time balance along the hierarchy (company → building/station → level/line → board → asset) and specific indicators (kWh/m³, kWh/bed, kWh/pupil, kWh/tonne).
The energy – asset condition relationship Increased consumption by a pump or blower goes unnoticed until a mechanical or electrical failure. Energy as a diagnostic tool: deviation from the baseline gives early warning of wear, clogging or incorrect settings.
Alarm management Numerous local alarms, unprioritized or lost without a trace; no link with maintenance teams. A single Alert → UEAM Ticket flow: triage by criticality, assignment to a specialized team, SLA deadline and post-intervention confirmation.
Data continuity Network outages create permanent gaps in the measurement history. Local Edge / EFFI-100 unit with buffer: local storage with timestamps and automatic resynchronization without duplicates.
Safety & Seismic Protection Uncorrelated systems; after an incident there is no centralized record of the checks needed before returning to service. DASS M95 XL integration: certified local transition to a safe state + automatic tickets in UEAM for tightness/circuit checks.
Energy Audit & ISO 50001 Laborious manual collection for ANRE, ISO 50001 or CSRD reporting; estimated savings with no measured proof. Normalized baseline and automatic reports, supported by certified energy auditors (Law 121/2014) and a 100% audit trail.
Quick Configuration · 4 Questions

Self-assessment to define the scope of a MOBIUS OEAM pilot

Select the options specific to your organization to automatically pre-fill the technical assessment request and the pilot project proposal.

Your answers will be transferred automatically to the details field of the form below.
Frequently Asked Questions (FAQ)

Technical, security and implementation clarifications

Does MOBIUS OEAM replace SCADA, BMS or local protections?

No. The platform and the EFFI-100 equipment complement existing SCADA, BMS and automation without replacing them. Electrical protections, the fire alarm panel, the gas detector and the legal emergency procedures remain the local command authority.

What happens if the internet connection is interrupted at a station or building?

The local gateway (Edge / EFFI-100 unit) validates and timestamps the data and temporarily keeps it in the local buffer; when the connection is restored, it automatically and securely retransmits it to the platform, with no losses and no duplicate records.

How are the energy savings reported in the project validated?

Savings are not based on generic promises; they are established after measuring a reference period (baseline), normalized for volume, flow, outdoor temperature, occupancy and operating regime, and then verified through the pilot project.

Do you also offer Energy Audit services under Law no. 121/2014?

Yes. Beyond the software platform and the EFFI-100 hardware component, the MOBIUS team offers energy audit services carried out by ANRE-certified energy auditors and assistance in defining EnPI indicators according to ISO 50001.

Technical Assessment & Pilot Project

Talk to the MOBIUS team about your infrastructure.

Send your request directly from this page — with no need for an email client in the browser and no additional validation steps. The MOBIUS technical team will analyze the proposed scope and contact you to arrange a technical visit or a demo.

What the initial assessment proposal includes:

  • ✓ Diagnosis of existing data sources, electrical boards, meters and SCADA/BMS integrations
  • ✓ Choosing a representative pilot scope (e.g. 1 DWTP/WWTP station, the technical basement + 1 clinical level in a hospital, 1 school building or 1 group of buildings + a county road section)
  • ✓ Defining specific indicators (EnPIs / KPIs), the reference profile and clear acceptance criteria
  • ✓ Configuring the dashboard and the alert and ticket flow in MOBIUS OEAM + UEAM
Direct contact MOBIUS Software SRL:
Email: office@mobiussoftware.ro · contact@mobiussoftware.ro
Phone: +40 722 377 877 · Office: 24 Mihail Sebastian St., Bucharest

Request a MOBIUS OEAM Assessment / Demo

Direct and secure transmission to the MOBIUS Software server.

MOBIUS OEAM Documentation Center

Download the Official MOBIUS OEAM Brochure and the Sector Technical Presentations (PDF)

All documents are available free of charge in PDF format for technical analysis within your team.

Official Product Brochure MOBIUS OEAM Brochure — Overview 22 A4 pages (2026 Edition, English version) · Concept, 7 modules + UEAM, EFFI-100, M95 XL and the 4 sector architectures.
📄 Download the Brochure (PDF)
Water-Sewage Solution Water and Sewage Companies · EFI 100 35 pages · DWTP, DMA, pumping stations, WWTP, Bioreactor, Energy Audit & UI appendix.
📥 Water-Sewage PDF (35 pages)
Health Solution Hospitals and Medical Facilities · effiPower 29 pages · Operating theater, ICU, Oxygen, HVAC, M95 XL seismic protection.
📥 Hospitals PDF (29 pages)
Education Solution Schools, High Schools and Educational Campuses 27 pages · Energy, CO₂ in classrooms, sports grounds, QR-coded equipment, safety.
📥 Schools PDF (27 pages)
County Administration County Council · Buildings, DGASPC & Roads 24 pages · County Council property, DGASPC, GIS Roads in UEAM & AST Permits.
📥 County Council PDF (24 pages)